HR1101CL HR1101CS HR1102CL HR1102CS HR1103CL HR1103CS
Power 1kVA/1kW 2kVA/2kW 3KVA 3KVA
Battery Cold Start Standard
Input voltage range 110VAC~300VAC
50% load@ 276VA~C300VAC;100% load@176VAC~276VAC;110VAC~176VAC load decrease linearly from 100%~50%
Phase Single Phase in, Single Phase out
Rated voltage 220/230/240VAC
Line low transfer 110VAC
Line low recovery 120VAC
Line high transfer 300VAC
Line high recovery 290VAC
Input curent
Rated Current 4.9A 9.7A 14.5A
Input Power Factor ≥0.99
THDi <3% (100% Linear load); <5% (non-linear load)
Input frequency Range 50/60±5Hz,±1Hz/±3Hz/±10Hz(Settable)
Output
Frequency adaptable Settable
Output Voltage
Waveform(Bat. Mode) Pure Sine Wave
Rated voltage 220/230/240VAC, 200/208VAC(PF=0.9)
Voltage regulation ± 1%
Dynamic response ≤5% (0% – 100% -0%)
Dynamic recovery ≤40ms (0% – 100% -0%)
Voltage distortion <3% (100% Linear load); <5% (non-linear load)
Output Frequency
Synchronization range Mains mode: follow the mains frequency,Battery mode: 50/60Hz±0.1%
Transfer Time
Line mode to battery mode 0
Inverter to bypass 2ms
Effciency
Line mode with fully charged battery 94.5%@100% load 95%@100% load 95.5%@100% load
ECO mode 98.0% 98.0% 98.0%
Battery mode 89.5%@100% load 91.5%@100% load 91.5%@100% load
Noise (1m away) <43dB@<60%load, <47dB@>60%load <50dB@<60%load, <55dB@>60%load <50dB@<60%load, <55dB@>60%load
Overload Capability (Inverter) 102%~110%: Transfer to bypass after 30mins
110%~125%: Transfer to bypass after 10mins
125%~150%: Transfer to bypass after 30s
Overload Capability (Battery Mode) 102%~110%: Transfer to bypass after 1min
110%~125%: Transfer to bypass after 10s
125%~150%: Shutdown after 5s
Overload Capability (Bypass Mode) <130%: Long time operation
130%~150%: Shutdown after10mins
150%~180%: Shutdown after 5s
Crest Factor 3:1
BATTERY
Rating/Type Depend on the capacity of external batteries 12VDC/7Ah Depend on the capacity of external batteries 12VDC/7Ah Depend on the capacity of external batteries 12VDC/9Ah
Quantity 3 6 6
DC Voltage 36VDC/48VDC
(Support lithium battery)
36VDC 72VDC/96VDC
(Support lithium battery)
72VDC 96VDC
(Support lithium battery)
72VDC
Back-up Time Depend on the capacity of external batteries 3mins @80% load Depend on the capacity of external batteries 3mins @80% load Depend on the capacity of external batteries 3mins @80% load
Battery Charger
Charging Voltage
Charging Current 1-12A (Settable) 1A 1-12A (Settable) 1A 1-12A (Settable) 1A
Charging Time Depend on the capacity of external batteries 8h recharge to 90% Depend on the capacity of external batteries 8h recharge to 90% Depend on the capacity of external batteries 8h recharge to 90%
INDICATOR & ALARM
Display LED+LCD
Battery Discharge Sound once every 2 minutes
Low Battery Voltage Sound once every 6s
Overload Continuous beeping
Input Voltage Abnormal (Include Sequential Negative,Ground wire not connected) Sound once every 2 minutes
Alarm Sound once every 6s
Fault Continuous beeping
INTERFACE
RS232 Support background software through standard cables
Input IEC C14 IEC C20
Output 4 National standard sockets
OPTION
SNMP Card Monitor the machine through the network
AS400 Dry Contact Pluggable DB9 dry connector card or phoenix terminal
USB B-type USB port
RS485 RS485 communication interface
EPO Emergency power off
External Battery Temperature External battery temperature detection
RJ45 Surge Protection Port Surge Protection
BMS Dry contact for Lithium Battery BMS
MECHANICAL
W*D*H(mm) 440*377*86 440*427*86 440*427*86 440*577*86 440*427*86 440*577*86
W*D*H(mm)
(Package size)
580*515*250 580*565*250 580*565*250 580*717*250 580*565*250 580*717*250
Net weight (KG) 5.5 12.8 7 21.9 7.3 24.9
Gross weight (KG) 8.2 15.7 9.9 25.2 10.2 28.2
Color Black
Batery Box (VRLA) Dimension 440*426*86